Control Panel VKEY 100 / external keyboard – adjusting the resistance of T-Bar’s movement
On the right side of the panel a hidden inspection space is provided for that purpose. In order to remove the panel, we will use a hex screwdriver with an appropriate blade length – 11 cm. Use anti-clockwise motion and remove two screws that secure the panel.
Hold down the panel and secure the fastening screws. Remove the panel from the keyboard housing.The right hole is used for inspecting interior of the housing. The left hole is used for adjusting the T-BAR with a screwdriver.
Set the T-BAR in the middle position. An adjustment screw will appear in the hole.
Insert the screwdriver into the hole placing it on the screw head.Clockwise motion increases the resistance of T-BAR’s movement, while anti-clockwise decreases it.