Control Panel VKEY 100 / external keyboard – calibration of joystick and T-Bar
Simultaneously press the following buttons:DELEGATION A , DELEGATION DSK 2 and and LOCK.
5 buttons will light up signaling execution of a test for example, communication F1.
The second test is JOYSTICK’s calibration.Move it to the right and to the left to its extreme positions. When it’s completed, the F2 LED will light up in white.
Now let’s move the joystick up and down to its extreme positions.When you complete that, the F3 LED will light up in white.
F4 is the JOYSTICK’s knob calibration.We turn it several times to the right and to the left to the extreme positions.When you complete that, the F4 LED will light up in white.
F5 test is the T-BAR’s calibration.Move the T-BAR to its extreme positions.
After several movements, all the LEDs will go out. This way, the keyboard has been calibrated and has returned to its normal operation mode.